MAIN CIRCUIT BREAKER LOAD CENTER
EATON
CH32B200J
LOADCENTER
MAIN BREAKER; 120/240 VAC; 200 AMPERE; 32 MAXIMUM CIRCUIT(S); CSR MAIN BREAKER; BREAKER MOUNTING PLUG ON; INTERRUPTING RATING 25 KILOAMPERE; BONDED SPLIT NEUTRAL; COPPER BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 2 AWG TO 300 KCMIL (ALUMINUM/COPPER); NEMA 1, INDOOR ENCLOSURE; ENCLOSURE SIZE DESIGNATION J; SIZE 14-5/16 INCH W X 3-7/8 INCH D X 34-1/8 INCH H; APPROVAL UL; CH MODEL

Show all:  Single Phase Main Breaker Load Centers

 Spec Sheet   |   More Details
IN STOCK
LOAD CENTER COVER
EATON
CH8JF
PANEL COVER
INDOOR COVER; ENCLOSURE SIZE DESIGNATION J; FLUSH/SURFACE MOUNTING; CH MODEL

Show all:  Load Center Covers

 Spec Sheet   |   More Details
IN STOCK
MAIN CIRCUIT BREAKER LOAD CENTER
EATON
CH42B200K
LOADCENTER
MAIN BREAKER; 120/240 VAC; 200 AMPERE; 42 MAXIMUM CIRCUIT(S); CSR MAIN BREAKER; BREAKER MOUNTING PLUG ON; INTERRUPTING RATING 25 KILOAMPERE; BONDED SPLIT NEUTRAL; COPPER BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 2 AWG TO 300 KCMIL (ALUMINUM/COPPER); NEMA 1, INDOOR ENCLOSURE; ENCLOSURE SIZE DESIGNATION K; SIZE 14-5/16 INCH W X 3-7/8 INCH D X 37 INCH H; APPROVAL UL; CH MODEL

Show all:  Single Phase Main Breaker Load Centers

 Spec Sheet   |   More Details
IN STOCK
LOAD CENTER COVER
EATON
CH8CF
PANEL COVER
INDOOR COVER; ENCLOSURE SIZE DESIGNATION C; FLUSH/SURFACE MOUNTING; CH MODEL

Show all:  Load Center Covers

 Spec Sheet   |   More Details
IN STOCK
MAIN CIRCUIT BREAKER LOAD CENTER
EATON
BR3040B200
LOADCENTER
MAIN BREAKER; 120/240 VAC; 200 AMPERE; 40 MAXIMUM CIRCUIT(S); (30) 1 INCH MAXIMUM SPACE(S); BW MAIN BREAKER; INTERRUPTING RATING 10000 AMPERE; BONDED SPLIT NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 2 AWG TO 300 KCMIL (ALUMINUM/COPPER); NEMA 1, INDOOR ENCLOSURE; FLUSH/SURFACE COVER; ENCLOSURE SIZE DESIGNATION G1; SIZE 14-5/16 INCH W X 3-7/8 INCH D X 34-1/8 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC

Show all:  Single Phase Main Breaker Load Centers

 Spec Sheet   |   More Details
IN STOCK
LOAD CENTER PANEL COVER
EATON
CH8KFM
FLUSH LOAD CENTER COVER
MECHANICAL INTERLOCK; CH BREAKER; FLUSH MOUNTING; USED ON CH42B200K/CH42N200K/CH42B225K LOADCENTER; CH MODEL

Show all:  Load Center Covers

 Spec Sheet   |   More Details
IN STOCK
LOAD CENTER COVER
EATON
CH8BF
PANEL COVER
INDOOR COVER; ENCLOSURE SIZE DESIGNATION B; FLUSH/SURFACE MOUNTING; CH MODEL

Show all:  Load Center Covers

 Spec Sheet   |   More Details
IN STOCK
LOAD CENTER COVER
EATON
CH8KF
PANEL COVER
INDOOR COVER; ENCLOSURE SIZE DESIGNATION K; FLUSH/SURFACE MOUNTING; CH MODEL

Show all:  Load Center Covers

 Spec Sheet   |   More Details
IN STOCK
MAIN CIRCUIT BREAKER LOAD CENTER
EATON
BR2040B200
LOADCENTER
MAIN BREAKER; 120/240 VAC; 200 AMPERE; 40 MAXIMUM CIRCUIT(S); (20) 1 INCH MAXIMUM SPACE(S); BW MAIN BREAKER; INTERRUPTING RATING 10000 AMPERE; BONDED SPLIT NEUTRAL; TIN PLATED ALUMINUM BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 2 AWG TO 300 KCMIL (ALUMINUM/COPPER); NEMA 1, INDOOR ENCLOSURE; FLUSH/SURFACE COVER; ENCLOSURE SIZE DESIGNATION D1; SIZE 14-5/16 INCH W X 3-7/8 INCH D X 29-1/8 INCH H; APPROVAL UL 50, UL 67, UL 489, UL 869; BR MODEL; APPLICABLE STANDARD NEC

Show all:  Single Phase Main Breaker Load Centers

 Spec Sheet   |   More Details
IN STOCK
MAIN LUG LOAD CENTER
EATON
CH24L125C
LOADCENTER
MAIN LUG; 120/240 VAC; 125 AMPERE; 24 MAXIMUM CIRCUIT(S); BREAKER MOUNTING PLUG ON; GROUNDABLE NEUTRAL; COPPER BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 6 TO 2/0 AWG (ALUMINUM/COPPER); NEMA 1, INDOOR ENCLOSURE; ENCLOSURE SIZE DESIGNATION C; SIZE 14-5/16 INCH W X 3-7/8 INCH D X 21 INCH H; APPROVAL UL; CH MODEL

Show all:  Single Phase Main Lug Load Centers

 Spec Sheet   |   More Details
IN STOCK
LOAD CENTER PANEL COVER
EATON
CH8JFM
FLUSH LOAD CENTER COVER
MECHANICAL INTERLOCK; CH BREAKER; FLUSH MOUNTING; USED ON CH32B150J/CH32B200J/CH3242B200J/CH32N200J/CH32B225J LOADCENTER; CH MODEL

Show all:  Load Center Covers

 Spec Sheet   |   More Details
IN STOCK
EATON
CH50SPAST
LOADCENTER SPA PANEL

Show all:  Load Center Accessories

 More Details
IN STOCK
MAIN LUG LOAD CENTER
EATON
CH16L125B
LOADCENTER
MAIN LUG; 120/240 VAC; 125 AMPERE; 16 MAXIMUM CIRCUIT(S); BREAKER MOUNTING PLUG ON; GROUNDABLE NEUTRAL; COPPER BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 6 TO 2/0 AWG (ALUMINUM/COPPER); NEMA 1, INDOOR ENCLOSURE; ENCLOSURE SIZE DESIGNATION B; SIZE 14-5/16 INCH W X 3-7/8 INCH D X 16-3/4 INCH H; APPROVAL UL; CH MODEL

Show all:  Single Phase Main Lug Load Centers

 Spec Sheet   |   More Details
IN STOCK
MAIN CIRCUIT BREAKER LOAD CENTER
EATON
CH32B200R
LOADCENTER
MAIN BREAKER; 120/240 VAC; 200 AMPERE; 32 MAXIMUM CIRCUIT(S); CSR MAIN BREAKER; BREAKER MOUNTING PLUG ON; INTERRUPTING RATING 25 KILOAMPERE; BONDED SPLIT NEUTRAL; COPPER BUS MATERIAL; BOTTOM FEED LOCATION; MAIN WIRE SIZE 2 AWG TO 300 KCMIL (ALUMINUM/COPPER); NEMA 3R, OUTDOOR ENCLOSURE; ENCLOSURE SIZE DESIGNATION J; SIZE 14-5/16 INCH W X 5-3/16 INCH D X 34-1/8 INCH H; APPROVAL UL; CH MODEL

Show all:  Single Phase Main Breaker Load Centers

 Spec Sheet   |   More Details
MAIN LUG LOAD CENTER
EATON
CH12L125B
12 CIRCUIT PANEL
MAIN LUG; 120/240 VAC; 125 AMPERE; 12 MAXIMUM CIRCUIT(S); BREAKER MOUNTING PLUG ON; GROUNDABLE NEUTRAL; COPPER BUS MATERIAL; BOTTOM/TOP FEED LOCATION; MAIN WIRE SIZE 6 TO 2/0 AWG (ALUMINUM/COPPER); NEMA 1, INDOOR ENCLOSURE; ENCLOSURE SIZE DESIGNATION B; SIZE 14-5/16 INCH W X 3-7/8 INCH D X 16-3/4 INCH H; APPROVAL UL; CH MODEL

Show all:  Single Phase Main Lug Load Centers

 Spec Sheet   |   More Details
IN STOCK
* E=Each, C=100, M=1000
First Previous  Page   of  6  Next Last
 
 


5320 LACEY BLVD., S.E. LACEY, WA 98503 | Tel: 360-923-2345 | Fax: 360-459-9750 | customerservice@cedlacey.com
Terms of Use | Terms and Conditions
3.5.4